Error Table - Omron CJ1W-CT021 Operation Manuals

For nj-series cpu unit. high-speed counter units.
Hide thumbs Also See for CJ1W-CT021:
Table of Contents

Advertisement

5-3-2

Error Table

The errors that may occur for this Unit are listed below. Event levels are given in the table as follows:
Maj: Major fault level
Prt: Partial fault level
Min: Minor fault level
Obs: Observation
Info: Information
Refer to the NJ-series Troubleshooting Manual (Cat. No. W503) for all of the event codes that may
occur in an NJ-series Controller.
Event code
Event name
6801 0000 hex
Unit Error
CJ-series High-speed Counter Units Operation Manual for NJ-series CPU Unit(W492)
5 Error Processing, Maintenance and Inspection
Meaning
Assumed cause
An error occurred in
• There is an error in the Special
the High-speed
Unit Setup.
Counter Unit.
• An overflow or underflow error
occurred.
• An illegal preset value was
used.
• A CPU Unit monitor error or bus
error occurred.
Level
Maj
Prt
Min
Obs Info
page 11
Reference
5
5-9