Output Pulse Duration
A Digital Output that is configured to have an Output Pulse Duration turns ON immediately and will
stay ON for the specified Pulse Duration. After the Pulse Duration has elapsed the Digital Output
turns OFF.
Additional Information
The output status is reflected in "*_OutStaDat" (output (external output + internal output) sta-
tuses). When the programmable output ON function is allocated to external output, the external
output status, including output ON delay and output ON hold, is reflected in Bit 00 and Bit 01 of
this variable.
Configuring Programmable Output Pulses
Name of device variable
for CJ-series Unit
*_OutOnDelayTm0Cfg
*_OutDur0Cfg
*_OutOnDelayTm1Cfg
*_OutDur1Cfg
Additional Information
• A Digital Output to which an Output ON-Delay or Output Pulse is applied will turn OFF immedi-
ately after the corresponding Output (0-1) of the Output Pattern has turned OFF. An Output
Pulse ON-Delay or Output Pulse Duration in progress will be reset immediately and the Digital
Output is turned OFF or stays OFF.
• If an Output is switched ON manually (refer to 3-5-3 Manual Output Control) and Programma-
ble Output Pulse functionality has been assigned to that Output, then this functionality will not
be applied to the Output. Instead, the Output is switched ON immediately.
• When applying an Output Pulse to a turn OFF a Digital Output, the output will appear to be
OFF, but internally it will be treated as ON until it is reset when the range conditions are met or
target is matched. If an attempt is made to set the output, the system will assume that it is
already ON and it will remain OFF. Particularly with target values, configure reset conditions
for output carefully.
CJ-series High-speed Counter Units Operation Manual for NJ-series CPU Unit(W492)
Type
Name
WORD
Output Pulse Turn ON-
Delay Time (BCD) Dig-
ital Output 0
WORD
Output Pulse Duration
(BCD) Digital Output 0
WORD
Output Pulse Turn ON-
Delay Time (BCD) Dig-
ital Output 1
WORD
Output Pulse Duration
(BCD) Digital Output 1
3 Operation and Configuration
Function
Sets the output ON delay time for external
output 0. When this is set to 16#0000, the
function operates normally.
Data range: 16#0000 to 9999 (BCD)
Unit: ms
Sets the output ON hold time for external
output 0.
When this is set to 16#0000, the function
operates normally.
Data range: 16#0000 to 9999 (BCD)
Unit: ms
Sets the output ON delay time for external
output 1. When this is set to 16#0000, the
function operates normally.
Data range: 16#0000 to 9999 (BCD)
Unit: ms
Sets the output ON hold time for external
output 1.
When this is set to 16#0000, the function
operates normally.
Data range: 16#0000 to 9999 (BCD)
Unit: ms
3
3-41