Omron CJ1W-CT021 Operation Manuals page 110

For nj-series cpu unit. high-speed counter units.
Hide thumbs Also See for CJ1W-CT021:
Table of Contents

Advertisement

3 Operation and Configuration
Example Comparison Mode with Linear Counter
Lower Count Limit
−2,147,483,648
Output 0
Output 1
Soft Output 2
Soft Output 3
CV
In this example 7 Comparison Values are specified. On reaching a Comparison Value an Output
can be Set or Reset depending on the crossing direction. If the CV is crossed in the positive count-
ing direction (+CV crossing) or negative counting direction (−CV crossing), one or multiple Outputs
can be Set (S) or Reset (R).
For example Output 0 is Set on crossing CV5 in the positive counting direction and Reset on cross-
ing CV7 in the negative counting direction. The crossing of CV3 in the positive counting direction
results in the Setting of Output 2 and the Resetting of Output 1.
3-30
Counter Value
CV1
CV2
CV3
= Set in positive (+) direction
= Set in negative (−) direction
Value
CV Crossing
+CV crossing
−87,000
1
−CV crossing
+CV crossing
−56,000
2
−CV crossing
+CV crossing
−15,000
3
−CV crossing
+CV crossing
4
+18,000
−CV crossing
+CV crossing
5
+46,000
−CV crossing
+CV crossing
6
+70,000
−CV crossing
+CV crossing
7
+108,000
−CV crossing
CJ-series High-speed Counter Units Operation Manual for NJ-series CPU Unit(W492)
Upper Count Limit
+2,147,483,647
0
CV4
CV5
CV6
CV7
= Reset in positive (+) direction
= Reset in negative (−) direction
Out0
Out1
Soft2
R
R
S
S
S
R
R
R
Soft3
R
S
R