Reset Enable Bit as Reset Enable Source
To execute a reset (or preset a Counter Value to 0) by using either Digital Input or a Z phase signal,
it is necessary to set the following device variables for CJ-series Unit (for output) to 1.
Name of device variable
for CJ-series Unit
*_Ch1_RstEnbl
*_Ch2_RstEnbl
Digital Input as Reset Enable Source
In order to use a Digital Input as Reset Enable Source you must assign Function 15 or 16
(= Enable/Disable Reset) to the corresponding Digital Input. Refer to 3-4 Digital Input Functions for
more information.
CJ-series High-speed Counter Units Operation Manual for NJ-series CPU Unit(W492)
Type
Name
BOOL
Reset Enable
3 Operation and Configuration
Function
0: Disable
1: Enabled
3