Replacement Of Smb Battery - ABB IRB 6640 - 180/2.55 Product Manual

Articulated robot
Table of Contents

Advertisement

3 Maintenance

3.4.8. Replacement of SMB battery

3.4.8. Replacement of SMB battery
Location of SMB battery
The SMB battery (SMB = serial measurement board) is located on the left hand side of the
frame as shown in the figure below.
xx0600003444
A
B
C
D
Required equipment
Equipment, etc.
Battery pack
Standard toolkit
Circuit Diagram
Removal, battery
The procedure below details how to remove the SMB battery.
172
Cover, battery box
Battery pack
Cable, battery
Battery holder
Spare part no.
3HAC16831-1
-
-
3HAC025744-001
Action
1. Move the robot to its calibration position.
Note
Battery includes protection circuits. Replace it
only with given spare part no. or an ABB
approved equivalent.
The content is defined in section
toolkit on page
394.
See chapter
Circuit
diagram.
Note
This is done in order to facilitate the
updating of the revolution counter.
Continues on next page
3HAC026876-001 Revision: C