YASKAWA VS-616PS5 Series Programming Manual page 50

Brushless motor drive
Hide thumbs Also See for VS-616PS5 Series:
Table of Contents

Advertisement

Section F: Option Parameters
F1 PG Option Set-up
F1-05 PG Rotation Selection
Sets the relationship between the motor rotation direction and PG polarity. (Hall sen-
sor HS4 & HS5 or encoder channel A & B).
The motor's rotation direction applies when viewing the motor shaft from the load
side.
F1-08 Overspeed Detection Level
Setting Range:
Factory Default:
This parameter sets the motor overspeed detection level as a percentage of maxi-
mum output speed (E1-06). Used in conjunction with parameter F1-09 to sense an
overspeed condition.
F1-09 Overspeed Detection Time
Setting Range:
Factory Default:
Sets the elapsed time from when an overspeed condition is detected to when a fault
(or alarm) occurs.
Overspeed Level (F1-08)
Overspeed Fault Signal
A fault signal is output to stop operation after the absolute value of the motor speed
exceeds the set value of F1-08 for the time set to F1-09. The stopping method is set
by F1-03.
50
Setting
0
HS5 leads HS4 (channel B leads A) in FWD direction.
1
HS4 leads HS5 (A leads B) in FWD direction (factory default).
0 to 120%
115%
0.0 to 2.0s
0.0s
0
Figure 29 Overspeed Detection Timing Diagram
Description
|
Motor Speed
OFF
F1-09
VS-616PS5 Programming Manual
|
ON
Q
A
A

Advertisement

Table of Contents
loading

Table of Contents