E1-04 Motor Rated Current
Setting Range:
Factory Default:
Set to the motor rated current as indicated on the motor nameplate for motor capacity
7.5kW or less is set in units of 0.01A, and for motor capacity 11kW or greater, in units
of 0.1A.
E1-05 Number of Motor Poles
Setting Range:
Factory Default:
Use this parameter to set the number of motor poles.
E1-06 Maximum Motor Speed
Setting Range:
Factory Default:
Set the maximum motor speed with this parameter in units of 1rpm. Avoid the con-
stant horsepower range due to lack of field weakening control in the brushless DC
machine.
E1-07 Base Motor Speed
Setting Range:
Factory Default:
Base motor speed is set in units of 1rpm.
.
E1-08 Minimum Motor Speed
Setting Range:
Factory Default:
The minimum motor operating speed is set in units of 1rpm.
VS-616PS5 Programming Manual
0.0 to 605.0
0.00 (E1-02=1000)
2, 4, 6, or 8
4 (E1-02=1000)
0 to 6000rpm
1 (E1-02=1000)
0 to 6000rpm
1 (E1-02=1000)
0 to 6000rpm
30 (E1-02=1000)
Section E: Motor Parameters
E1 V/f Pattern
Q
Q
Q
Q
Q
45