Section B: Application Parameters
B3 Magnetic Pull-in
B3-05 Magnetic Pull-in Time
Setting Range:
Factory Default:
This parameter sets the time to allow the rotor to pull in (align) with the magnetic field
at initial excitation. Pull-in waiting time is set in units of 0.1s.
The current vs. time plot during the magnetic pull-in process is as follows:
Operation Status
Slow Start
Insufficient torque, and
"STO" is output
16
0.0 to 5.0s
1.0s
Current Value
B3-02
0
1
2
B3-04 B3-05
B3-02 Adjustment
-
Increase set value.
Time
B3-04 Adjustment
B3-05Adjustment
Decrease set value
Decrease set value
-