YASKAWA VS-616PS5 Series Programming Manual page 47

Brushless motor drive
Hide thumbs Also See for VS-616PS5 Series:
Table of Contents

Advertisement

E1-16 Motor Feeder Resistance
Setting Range:
Factory Default:
Wiring resistance between the inverter and the motor is set by a percentage value of
the inverter's rated voltage.
Where:
R
feed
R
= Feeder resistance (Ω)
f
I
= Rated current (E1-04) (A)
m
V
= Inverter rated voltage (E1-03) (V)
b
E1-17 Motor Connection Selection
Setting Range:
Factory Default:
Sets the winding connection configuration for the connected motor. Used only when
using the winding data look-up tables, E1-02 is not equal to 1000 (see Installation &
Quick Start Manual). Set E1-17 to the proper configuration first, then set E1-02 to the
proper winding code. This parameter is not used if E1-02=1000.
0: 1∆ Connection:
VS-616PS5 Programming Manual
0.0 to 10.0%
1.0
R
feed
= Percent wiring resistance between inverter and motor
0 to 3
0
×
R f I m
×
----------------- -
100
=
V b
------ -
3
·
Section E: Motor Parameters
E1 V/f Pattern
T
·
1
T
·
2
T
3
A
A
47