Section E: Motor Parameters
E1 V/f Pattern
E1-09 Motor Terminal to Terminal Resistance
Setting Range:
Factory Default:
Set the terminal to terminal resistance of the motor in units of 0.001Ω.
E1-10 Motor d Axis Inductance
Setting Range:
Factory Default:
The d Axis inductance is set in units of 0.01mH.
E1-11 Motor q Axis Inductance
Setting Range:
Factory Default:
This parameter sets the q Axis inductance in units of 0.01mH at the time the motor-
rated load is established. Set this value equal to the setting in parameter E1-10 for
surface magnet PM motors.
E1-13 Induced Voltage Constant
Setting Range:
Factory Default:
This parameter sets the induced voltage RMS value for the motor in units of 0.1V/
1000 RPM. Enter the induced voltage generated at 1000 RPM motor speed. Make
sure the induced voltage at the maximum speed (E1-06 does not exceed the voltage
rating of the inverter.
Do not change the value after it has been set.
E1-15 Motor Mechanical Loss
Setting Range:
Factory Default:
The motor's mechanical loss is set in units of 0.1%. Used to improve torque linearity
The motor's rated output is 100%.
46
0 to 65.535Ω
0.000 (E1-02=1000)
0.00 to 600.00mH
0.00 (E1-02=1000)
0.00 to 600.00mΗ
0.00 (E1-02=1000)
20.0 to 500.0 V/1000 RPM
0.0 (E1-02=1000)
0.0 to 10.0%
0.0