YASKAWA VS-616PS5 Series Programming Manual page 13

Brushless motor drive
Hide thumbs Also See for VS-616PS5 Series:
Table of Contents

Advertisement

Setting
1
2
3
B1-06 LOCAL/REMOTE Run Select
This parameter determines how the inverter will function when switching from local to
remote operation when the external run command is applied.
VS-616PS5 Programming Manual
Baseblock (factory default)- No output to motor
Run at minimum output speed (E1-08).
Zero-speed operation (internal speed reference is set to "0")
Selection
0
Operation is disabled if the external run command is applied
prior to switching from local to remote. The run command
must be removed and re-applied to start operation.
1
Operation is enabled if the external run command is applied
prior to switching from local to remote.(factory default).
Section B: Application Parameters
Description
Description
B1 Sequence
A
13