Siemens SIMATIC ET 200SP Manual page 83

Motor starter (3rk1308-0**00-0cp0)
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Status commands
Query_Modes
List_Energy_Saving_Modes
Get_Mode
Query_Version
Query_Measurement
Get_Measurement_List
Get_Measurement_List_with_
object_number
Get_Measurement_Values
Get_Measurement_Values_
with_object_number
The SIMATIC ET 200SP motor starter operates with the following ProfiEnergy modes (PE
modes):
PE_Mode_ID = 255
PE_Mode_ID = 01
t
off
t
off_min
t
on
t
Pause_min
Motor starter (3RK1308-0**00-0CP0)
Manual, 12/2016, A5E34821005002A/RS-AB/002
Provides a list of supported energy-saving modes.
Provides the parameter values with which the energy-saving
function works.
Shows the implemented PROFIenergy profile.
Provides a list of supported measured values.
Provides a list of supported measured values and the associated
object number.
Provides the requested measured values.
Provides the requested measured values together with the object
number.
Time_to_Pause
Time_min_length_of_stay
Time_to_operate
Time_min_Pause
Ready to operate
Energy-saving mode
Time the starter requires in order to change to energy
saving mode. With the SIMATIC ET 200SP motor starter,
this time is always 100 ms.
Minimum time that the device spends or should spend in
saving mode.
With the SIMATIC ET 200SP motor starter: 150 ms
Time that will elapse before the starter changes back to the
operating state.
With the SIMATIC ET 200SP motor starter: 100 ms (due to
startup sequence)
Time that is compared with t
with the "Start_Pause" command to the motor starter);
if t
≥ t
, the device switches to saving mode.
Pause
Pause_min
Product overview
3.7 Functions
(is transferred together
Pause