Chapter 11 Description of Parameter SettingsAFE2000 Series
Settings
 This parameter is the response delay time after AFE unit receives communication command as
shown in the following.
RS-485 BUS
PC or PLC command
COM2Transmission Speed
Settings
 This parameter is used to set the transmission speed between the RS485 master (PLC, PC, etc.) and
AFE2000 unit.
COM2 Transmission Fault Treatment
Settings
 This parameter is set to how to react if transmission errors occur.
COM2 Time-out Detection
Settings
 It is used to set the transmission time between communication and keypad.
COM2 Communication Protocol
Settings
0.0~200.0ms
Handling time
of the AFE unit
4.8~115.2kbits/s
0: Warning and continue to operate
1: Warn and ramp to stop
2: Warn and coast to stop
3: No warning and continue to operate
0.0~100.0sec
0.0: No detection
0:7,N,1 for ASCII
1:7,N,2 for ASCII
2:7,E,1 for ASCII
3:7,O,1 for ASCII
4:7,E,2 for ASCII
5:7,O,2 for ASCII
6:8,N,1 for ASCII
7:8,N,2 for ASCII
8:8,E,1 for ASCII
9:8,O,1 for ASCII
10:8,E,2 for ASCII
11:8,O,2 for ASCII
11-94
Response Message
of the AFE unit
Response Delay Time
Factory Setting: 19.2
Factory Setting: 3
Factory Setting: 0.0
Factory Setting: 13