Chapter 14 CANopen Overview AFE2000 Series
Fault
occ
Short Circuit
Fault
ocS
Oc at stop
ovA
Ov at accel
Fault
ovn
Ov at normal SPD
Fault
ovS
Ov at stop
Fault
LvA
Lv at accel
Fault
Lvd
Lv at decel
Fault
Lvn
Lv at normal SPD
Fault
LvS
Lv at stop
Fault
PHL
Phase Lacked
Fault
oH1
IGBT over heat
Short-circuit is detected between upper
000DH
bridge and lower bridge of the
IGBT module.
Over-current at stop. Hardware failure in
000EH
current detection
Over-current during acceleration.
000FH
Hardware failure in current detection
Over-current during steady speed.
0010H
Hardware failure in current detection.
230V: 450Vdc; 460V: 900Vdc
Over-voltage at stop. Hardware failure in
0011H
current detection
DC BUS voltage is less than Pr.06.00
0012H
during acceleration.
DC BUS voltage is less than Pr.06.00
0013H
during deceleration.
DC BUS voltage is less than Pr.06.00 in
0014H
constant speed.
DC BUS voltage is less than Pr.06-00 at
0015H
stop
0016H
Phase Loss.
IGBT overheat
IGBT temperature exceeds protection
level.
0017H
1~15HP: 90℃
20~100HP: 100℃
14-122
2240H
1
2310H
1
3210H
2
3210H
2
3210H
2
3220H
2
3220H
2
3220H
2
3220H
2
3130H
2
4310H
3