Environment
Noise immunity
Operation /storage
Shock / vibration
resistance
Installation
PROFIBUS DP Connector
PIN
1
2
3
4
5
6
7
8
9
LED Indicator & Troubleshooting
There are 2 LED indicators on CMC-PD01. POWER LED displays the status of the working power. NET LED
displays the connection status of the communication.
POWER LED
LED status
Green light on
Power supply in normal status.
Off
No power
NET LED
LED status
Green light on
Normal status
CMC-PD01 is not connected to
Red light on
PROFIBUS DP bus.
Red light
Invalid PROFIBUS communication
flashes
address
Orange light
CMC-PD01 fails to communication
flashes
with AC motor drive.
ESD(IEC 61800-5-1,IEC 6100-4-2)
EFT(IEC 61800-5-1,IEC 6100-4-4)
Surge Teat(IEC 61800-5-1,IEC 6100-4-5)
Conducted Susceptibility Test(IEC 61800-5-1,IEC 6100-4-6)
Operation: -10ºC ~ 50ºC (temperature), 90% (humidity)
Storage: -25ºC ~ 70ºC (temperature), 95% (humidity)
International standards: IEC61131-2, IEC68-2-6 (TEST Fc)/IEC61131-2 & IEC
68-2-27 (TEST Ea)
PIN name
-
-
Rxd/Txd-P
Sending/receiving data P(B)
-
DGND
VP
-
Rxd/Txd-N
Sending/receiving data N(A)
-
Indication
Indication
Chapter 7 Option CardsAFE2000 Series
Definition
Not defined
Not defined
Not defined
Data reference ground
Power voltage – positive
Not defined
Not defined
--
Check if the connection between CMC-PD01 and AC
motor drive is normal.
--
Connect CMC-PD01 to PROFIBUS DP bus.
Set the PROFIBUS address of CMC-PD01 between 1 ~
125 (decimal)
Switch off the power and check whether CMC-PD01 is
correctly and normally connected to AC motor drive.
7-47
9
6
Treatment
Treatment
5
1