Siemens SINAMICS G120 List Manual page 972

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

M_act_filt T
p3233 [D]
Actual torque [Nm]
r0080
[0]
[6799.8]
M_thresh 3 upper
p2189 [D] (10000000.00)
M_thresh 3 lower
p2190 [D] (0.00)
M_thresh 2 upper
p2187 [D] (10000000.00)
M_thresh 2 lower
p2188 [D] (0.00)
M_thresh 1 upper
p2185 [D] (10000000.00)
M_thresh 1 lower
p2186 [D] (0.00)
n_act smth message [rpm]
r2169
[8010.2]
Load monit n_dev
p3231 [D]
Load monit n_act
p3230 [C]
(0)
+
Load_moni fail_det
p3232 [C]
(1)
<1>
The response to these faults can be defined.
<2>
Fault evaluation only with p2181 > 0 and p2193 > 0.
1
2
Signals and monitoring functions
Load monitoring
p2149.1
1
M [Nm]
0
Tolerance bandwidth
1
0
n_thresh 1
p2149.1
p2182 [D] (150.00)
n_thresh 2
p2183 [D] (900.00)
1
0
3
4
A07926 "Envelop characteristic, parameter not valid"
<2>
Load monit config
p2193 [D]
Load monit t_del
p2192 [D]
0
0
1
0
2
3
0
1/min
n_thresh 3
p2184 [D] (1500.00)
Load monit t_del
p2192 [D]
0
1
0
1,2,3
5
6
fp_8013_97_55.vsd
05.09.2017
V4.7.9
Load monit resp
p2181 [D]
ZSW monitor 2
r2198
r2198
.11
[2536.3]
T
1 = Load in the alarm range
Evaluation
r2198
r2198.12
[2536.3]
1 = Load in the fault range
Load monitoring disabled
(0)
A07920
(1)
Torque/speed too low
A07921
(2)
Torque/speed too high
A07922
(3)
Torque/speed outside tolerance
F07923
<1>
(4)
Torque/speed too low
F07924
<1>
(5)
Torque/speed too high
F07925
<1>
(6)
Torque/speed outside tolerance
ZSW monitor 2
T
F07936
r2198
1
r2198
.12
Drive: Load loss
1 = Load in the fault
range
7
8
Function diagram
- 8013 -
G120 CU250S-2
[2536.3]