[5] = Largest total utilization (max)
[6] = Reserved
[7] = Reserved
Dependency:
Refer to: r9976
Refer to: F01054, F01205
Note:
For index 3 ... 5:
The total utilizations are determined using all sampling times used. The largest total utilizations are mapped here.
The sampling time with the largest total utilization is displayed in r9979.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
r9976[0...7]
System utilization / Sys util
Access level: 3
Can be changed: -
Unit group: -
Min
- [%]
Description:
Displays the system utilization.
If the utilization is greater than 100%, fault F01054 is output.
Index:
[0] = Reserved
[1] = Computing time utilization
[2] = Reserved
[3] = Reserved
[4] = Reserved
[5] = Largest total utilization
[6] = Reserved
[7] = Reserved
Dependency:
Refer to: F01054, F01205
Note:
For index 1:
The value shows the total computing time load of the system.
For index 5:
The total utilization is determined using all sampling times used. The largest total utilization is mapped here. The
sampling time with the largest total utilization is displayed in r9979.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
r9999[0...99]
Software error internal supplementary diagnostics / SW_err int diag
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Diagnostics parameter to display additional information for internal software errors.
Note:
Only for internal Siemens troubleshooting.
p10001
SI Motion delay time for test stop at DO (processor 1) / SI t_delay DO P1
Access level: 3
Can be changed: C(95)
Unit group: -
Min
4.00 [ms]
Description:
Sets the delay time for testing the digital output.
Within this time, for a forced checking procedure of the digital output, the signal must have been detected via the
corresponding readback input (p10047).
Dependency:
Refer to: p10003, p10007, p10017, p10046
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
Calculated: -
Scaling: -
Unit selection: -
Max
- [%]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
2000.00 [ms]
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
- [%]
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
500.00 [ms]