14. USING A LINEAR SERVO MOTOR
(2) Absolute position linear encoder
When an absolute linear encoder is used, the reference home position is the position per 1048576
pulses (changeable with the third digit of [Pr. PL01]) with reference to the linear encoder home position
(absolute position data = 0).
In the case of a proximity dog type home position return, the nearest reference home position after
proximity dog off is the home position. The linear encoder home position can be set in any position. LZ
(Encoder Z-phase pulse) cannot be used.

14.3.4 Test operation mode in MR Configurator2

CAUTION
By using a personal computer and MR Configurator2, you can execute the positioning operation, the output
signal (DO) forced output, and the program operation without connecting the servo system controller.
POINT
The data set type home position return can also be carried out.
Linear servo
motor
0 mm/s
ON
Proximity dog
OFF
signal
Reference home
position
Linear servo motor
position
Linear encoder home position
Note. Changeable with [Pr. PL01].
The test operation mode is designed for checking servo operation. It is not for
checking machine operation. Do not use this mode with the machine. Always use
the linear servo motor alone.
If the servo motor operates abnormally, use EM2 (Forced stop 2) to stop it.
POINT
The content described in this section indicates the environment where the servo
amplifier and a personal computer are directly connected.
For the MR-J4 multi-axis servo amplifier, all axes go into the test operation
mode simultaneously, but only A-axis, B-axis, or C-axis can be operated.
When the test operation mode is selected with the test operation select switch
(SW2-1), the SSCNET III/H communication for the servo amplifier in the test
operation mode and the following servo amplifiers is blocked.
Home position return direction
Home position return speed
(Note)
1048576 pulses
1048576 pulses × n
14 - 20
Creep speed
Home position

Hide quick links: