5. PARAMETERS

5.2.5 Extension setting 2 parameters ([Pr. PE_ _ ])

No.
Symbol
PE01
**FCT1
Fully closed loop function selection 1
This parameter is not available with MR-J4W2-0303B6 servo amplifiers.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PE03
*FCT2
Fully closed loop function selection 2
This parameter is not available with MR-J4W2-0303B6 servo amplifiers.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PE04
**FBN
Fully closed loop control - Feedback pulse electronic gear 1 - Numerator
Set a numerator of electronic gear for the servo motor encoder pulse at the fully
closed loop control.
Set the electronic gear so that the number of servo motor encoder pulses for one
servo motor revolution is converted to the resolution of the load-side encoder.
This parameter is not available with MR-J4W2-0303B6 servo amplifiers.
PE05
**FBD
Fully closed loop control - Feedback pulse electronic gear 1 - Denominator
Set a denominator of electronic gear for the servo motor encoder pulse at the fully
closed loop control.
Set the electronic gear so that the number of servo motor encoder pulses for one
servo motor revolution is converted to the resolution of the load-side encoder.
This parameter is not available with MR-J4W2-0303B6 servo amplifiers.
PE06
BC1
Fully closed loop control - Speed deviation error detection level
Set [AL. 42.9 Fully closed loop control error by speed deviation] of.
When the speed deviation between the servo motor encoder and load-side encoder
becomes larger than the setting value, the alarm will occur.
This parameter is not available with MR-J4W2-0303B6 servo amplifiers.
Name and function
Explanation
Fully closed loop function selection
0: Always enabled
1: Switching with the control command of controller
(switching semi./full.)
Switching with the control
command of controller
Off
On
To enable the digit, select "Fully closed loop control mode
(_ _ 1 _)" of "operation mode selection" in [Pr. PA01].
When "Absolute position detection system" is "Enabled (_ _
_ 1)" in [Pr. PA03], setting "1" will trigger [AL. 37 Parameter
error].
For manufacturer setting
Explanation
Fully closed loop control error detection function selection
0: Disabled
1: Speed deviation error detection
2: Position deviation error detection
3: Speed deviation error/position deviation error detection
Position deviation error detection system selection
0: Continuous detection system
1: Detection system at stop (detected with command set to
"0")
For manufacturer setting
Fully closed loop control error reset selection
0: Reset disabled (reset by powering off/on enabled)
1: Reset enabled
Control system
Semi closed loop control
Fully closed loop control
5 - 48
Initial
Setting
value
range
[unit]
Refer to Name
and function
column.
Initial
value
0h
0h
0h
0h
Refer to Name
and function
column.
Initial
value
3h
0h
0h
0h
1
1 to
65535
1
1 to
65535
400
1 to
[r/min]
50000
Each/
Common
Each
Each
Each
Each
Each