11. OPTIONS AND PERIPHERAL EQUIPMENT

11.1.2 SSCNET III cable

(1) Model explanations
The numbers in the cable length field of the table indicate the symbol filling the underline "_" in the cable
model. The cables of the lengths with the symbols are available.
Cable model
0.15 m 0.3 m 0.5 m
MR-J3BUS_M
015
MR-J3BUS_M-A
MR-J3BUS_M-B
(Note)
Note. For cable of 30 m or less, contact your local sales office.
(2) Specifications
SSCNET III cable model
SSCNET III cable length
Optical
Minimum bend
cable
radius
(cord)
Tension strength
Temperature
range for use
(Note)
Ambience
External
appearance [mm]
Note. This temperature range for use is the value for optical cable (cord) only. Temperature condition for the connector is the same as
that for servo amplifier.
POINT
Do not look directly at the light generated from CN1A/CN1B connector of servo
amplifier or the end of SSCNET III cable. The light can be a discomfort when it
enters the eye.
Refer to app. 9 for long distance cable over 50 m and ultra-long bending life
cable.
Cable length
1 m
3 m
5 m
03
05
1
3
MR-J3BUS_M
0.15 m
25 mm
70 N
2.2 ± 0.07
10 m 20 m 30 m 40 m 50 m
5
10
20
30
40
Description
MR-J3BUS_M-A
0.3 m to 3 m
5 m to 20 m
Enforced covering cable
Cord: 25 mm
140 N
(Enforced covering cable)
-40 °C to 85 °C
Indoors (no direct sunlight)
No solvent or oil
4.4 ± 0.1
4.4 ± 0.1
6.0 ± 0.2
11 - 4
Bending
Application/remark
life
Using inside panel
Standard
standard cord
Using outside panel
Standard
standard cable
Long
Using long distance
50
bending
cable
life
MR-J3BUS_M-B
30 m to 50 m
Enforced covering cable
50 mm
Cord: 30 mm
420 N
(Enforced covering cable)
-20 °C to 70 °C
4.4 ± 0.4
7.6 ± 0.5
50 mm
980 N