3. SIGNALS AND WIRING

3.3.3 Wiring CNP1, CNP2, and CNP3

(1) Connector
Connector
Receptacle assembly
CNP1
03JFAT-SAXGFK-43
06JFAT-SAXYGG-F-
CNP2
KK
CNP3A
CNP3B
04JFAT-SAGG-G-KK
CNP3C
POINT
For the wire sizes used for wiring, refer to section 11.5.
When wiring, remove the power connectors from the servo amplifier.
Insert only one wire or ferrule to each wire insertion hole.
CNP1
CNP2
CNP3A
CNP3B
CNP3C (Note)
Note. For the MR-J4 3-axis servo amplifier
Table 3.1 Connector and applicable wire
Applicable wire
size
AWG 16 to 14
AWG 16 to 14
AWG 18 to 14
Servo amplifier
Stripped length
[mm]
J-FAT-OT-EXL (big size
11.5
side)
J-FAT-OT-EXL (small size
9
side)
J-FAT-OT-EXL (small size
9
side)
3 - 11
Open tool
Manufacturer
JST