4. STARTUP
(2) Operation procedure
1) Turn off the power.
2) Turn "ON (up)" SW2-1.
Turning "ON (up)" SW2-1 during power-on will not start the test operation mode.
3) Turn on the servo amplifier.
When initialization is completed, the decimal point on the first digit will blink.
Example: MR-J4 2-axis servo amplifier
When an alarm or warning also occurs during the test operation, the decimal point will blink.
4) Start operation with the personal computer.

4.5.2 Motor-less operation in controller

ON
1 2 3 4 5 6
After 1.6 s
Blinking
After 0.8 s
Blinking
POINT
Use motor-less operation which is available by making the servo system
controller parameter setting.
Connect the servo amplifier with the servo system controller before the motor-
less operation.
The motor-less operation is not used in the fully closed loop control mode, linear
servo motor control mode, and DD motor control mode.
Set SW2-1 to "ON (up)".
After 0.2 s
After 1.6 s
Blinking
After 0.2 s
After 0.8 s
Blinking
After 0.2 s
4 - 17
ON
1
2 3 4 5 6

Hide quick links: