CHARGING SYSTEM

BEFORE TROUBLESHOOTING

• Use a known-good battery for troubleshooting.
• Check that the connectors are connected securely.
• Read the circuit tester's operation instructions carefully, and observe the instructions during inspection.
• Disconnect the battery cable before continuity inspection.
CHARGING SYSTEM
TROUBLESHOOTING
Check the fuse
(page 11-7)
Normal
Check the charge / lamp coil
Normal
1A / 3A charge coil type:
Check the circuit protector
Normal
1A / 3A charge coil type:
Check the silicon rectifier
Normal
10A / 18A charge coil type:
Check the regulator rectifier
Normal
Check the harness connecting the charge
coil and battery for open or short circuit and
for proper connection.
If necessary, replace or repair the harness.
gx240ut2_gx270ut2_gx340ut2_gx390ut2
.
(page 8-10)
.
(page 11-6)
.
(page 11-6)
.
(page 11-7)
.
Abnormal
Replace the fuse
Abnormal
Replace the charge coil / lamp coil
(page 8-9)
Abnormal
Replace the circuit protector
Abnormal
Replace the silicon rectifier
Abnormal
Replace the regulator rectifier
(page 11-4)
.
.
(page 11-4)
(page 11-4)
.
(page 11-4)
.
.