62Z7B000.book 4 ページ 2012年9月27日 木曜日 午前10時21分
dummyhead
dummyhead
CHARGING SYSTEM
BEFORE TROUBLESHOOTING
• Use a known-good battery for troubleshooting.
• Check that the connectors are connected securely.
• Read the circuit tester's operation instructions carefully, and observe the instructions during inspection.
• Disconnect the battery cable before continuity inspection.
TROUBLESHOOTING
Check the fuse (page 11-7).
Normal
Check the charge / lamp coil (page 8-8).
Normal
Check the circuit protector (page 11-7).
Normal
Check the silicon rectifier (page 11-6).
Normal
Check the harness connecting the charge
coil and battery for open or short circuit and
for proper connection.
If necessary, replace or repair the harness.
8-4
Abnormal
Replace the fuse (page 11-4).
Abnormal
Replace the charge coil / lamp coil (page 8-7).
Abnormal
Replace the circuit protector (page 11-4).
Abnormal
Replace the silicon rectifier (page 11-4).