Bracket Unit Technical Data; Ptt System - Yamaha F150B Service Manual

Hide thumbs Also See for F150B:
Table of Contents

Advertisement

SPEC

Bracket unit technical data

PTT system

Item
PTT
Hydraulic pressure
Down (*1)
Up (*1)
Motor brush
Standard length
Wear limit
Motor commutator
Standard diameter
Wear limit
(*1) The figures are for reference only.
1-17
Specification
Unit
MPa (kgf/
2
cm
, psi)
MPa (kgf/
2
cm
, psi)
mm (in)
mm (in)
mm (in)
mm (in)
Model
F150B
5.9–8.8 (59.0–88.0, 855.5–1276.0)
9.8–11.8 (98.0–118.0, 1421.0–1711.0)
9.8 (0.39)
4.8 (0.19)
22.0 (0.87)
21.0 (0.83)
FL150B