Port VLAN ID Configuration

The Port PVID Configuration screen lets you assign a port VLAN ID (PVID) to an interface.
There are certain requirements for a PVID:
All ports must have a defined PVID.
If no other value is specified, the default VLAN PVID is used.
If you want to change the port's default PVID, you must first create a VLAN that includes
the port as a member.
Use the Port VLAN ID (PVID) Configuration screen to configure a virtual LAN on a port.
To configure PVID information:
1.
Select Switching> VLAN > Advanced > Port PVID Configuration.
2.
Select the interfaces for which you want to configure the PVID settings:
For information about how to select and configure one or more ports and LAGs, see
Configuring Interface Settings
3.
In the Configured PVID field, specify the PVID to assign to untagged or priority tagged
frames received on the selected interfaces.
4.
(Optionally) Use the VLAN Member and VLAN Tag fields to change the VLAN membership
and tagging for the selected interfaces.
The VLAN membership and tagging information can also be configured by using the
VLAN Membership screen.
5.
From the Acceptable Frame Types list, specify how you want the selected interfaces to
handle untagged and priority tagged frames.
Whichever you select, VLAN tagged frames will be forwarded in accordance with the
IEEE 802.1Q VLAN standard. The factory default is Admit All.
VLAN Only. The port will discard any untagged or priority tagged frames it receives.
Admit All. Untagged and priority tagged frames received on the port will be accepted
and assigned the value of the port VLAN ID for this port.
6.
From the Configured Ingress Filtering list, specify how you want the port to handle tagged
frames.
Enable. A tagged frame is discarded if this interface is not a member of the VLAN
identified by the VLAN ID in the tag. In an untagged frame, the VLAN is the port VLAN
ID specified for the port that received this frame.
Disable. all frames are forwarded in accordance with the 802.1Q VLAN bridge
specification. The factory default is disabled.
7.
Specify the default 802.1p priority assigned to untagged packets arriving at the port.
Possible values are 0–7.
8.
Click the Apply button.