4pt 802.3af + legacy. 4-Point Resistive Detection in 802.3af mode, followed by
Legacy Detection, is done.
Legacy. Only Legacy Detection is done.
The factory default is IEEE 802.
9.
Assign a Timer Schedule to the port. Select None to remove the timer schedule
assignment. The factory default is None. See
10.
Click the Apply button to send the updated configuration to the switch. Configuration
changes take effect immediately.
11.
Click the Cancel button to cancel the configuration on the screen. The data on the screen is
reset to the latest value of the switch.
12.
Click the Power Cycle Port(s) button to forcibly reset the PSE port.
The following table describes the non-configurable PoE Port Configuration data that is
displayed.
Table 32. PoE Port Configuration Non-Configurable Data
Field
Port
High Power
Max Power (mW)
Class
Output Voltage
Output Current
Output Power
Temperature
S3300 Smart Managed Pro Switch
Timer Schedule
Description
The interface for which data is to be displayed or configured.
Enabled when a particular port supports High Power Mode.
The maximum power in milliwatts that can be provided by the port.
The class of the Powered Device (PD) defines the range of power
a PD is drawing from the system. Class definitions are:
0. 0.44–16.2 watts
1. 0.44–4.2 watts
2. 0.44–7.4 watts
3. 0.44–16.2 watts
4. 0.44–31.2 watts
Current voltage being delivered to the device in Volts.
Current being delivered to the device in mA.
Current power being delivered to the device in milliwatts.
The temperature measured at this port of the PoE Controller. The
temperature is measured in degrees Celsius.
Configure System Information
93