Scale parameters and functions

8.20 DR 21 Total set point

8.20
DR 21 Total set point
8.20.1

Overview

The total set point is interpreted in AWI modes as the number of containers to be dosed in
continuous operation.
Table 8- 20
Variable
Data record
number
Length
Application
Version identi-
fier

Total set point

(Page 110)
Reserve
Reserve
Reserve
8.20.2
Total set point
The total set point is interpreted in AWI modes as the number of containers to be dosed in
continuous operation. For example, if a total set point of 20 is specified and continuous
operation is started, WP251 doses 20 containers in succession. Continuous operation is
ended after the 20th container, and DR 30 sets the status bit "Total set point reached". If
continuous operation is switched off in the interim or an active dosing is aborted, the counter
is restarted.
110
Assignment of data record 21
Remark
Contains no. of the
data record
Data record length
information
Information about
which application the
data record belongs to
Current data record
version information
Total set point for
continuous operation
Reserve
Reserve
Reserve
Type
Length
Rw De-
(bytes)
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
FLOAT
4
rw
FLOAT
4
rw
USHORT
2
rw
USHORT
2
rw
Min.
Max.
Modbus
fault
register
20
-
-
1634
20
-
-
1635
105
-
-
1636
1
1
65635
1637
0
0
-
1638
-
-
-
1640
-
-
-
1642
-
-
-
1643