Scale parameters and functions

8.4 DR 3 calibration parameters

5. In order to identify the load cell type and the installation location of your load cells enter the
Load cell manufacturer, Load cell order number and Location Designation of Sensor in the
data record DR70.
6. The details of the data data records and parameters are specified in the parameter
assignment tables.
8.3

DR 2 command code

DR 2 is a special data record used to transfer commands to the SIWAREX module by
SIWATOOL.
8.4
DR 3 calibration parameters
The calibration parameters need to be checked and if necessary modified for all scales.
The scale is basically defined by calibration parameters and calibration operation.
Procedure
● Check all parameters and modify them as required.
● Transfer the DR 3 data record from SIWATOOL to the scale.
● Calibrate the scale.
● Transfer the DR 3 data record from the scale to SIWATOOL.
Table 8-1
Assignment of data record 3
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information
Application
Information on which application the
DR belongs to
Version iden‐
Information on the current data record
tifier
version
Scale name
Maximum length and actual length of
header
string for scale name
Scale name
Scale name specified by user
(Page 62)
Weight unit
Maximum length and actual length of
header
string for weight unit (for example, g,
kg, t, ...)
Unit of
Weight unit
weight
(Page 63)
1)
60
Type
Lengt
Rw
h
(byte
s)
UINT
2
r
UINT
2
r
UINT
2
r
UINT
2
r
UBYTE[2]
2
rw
STRING[12]
12
rw
UBYTE[2]
2
rw
STRING[4]
4
rw
Operating Instructions, 08/2019, A5E33715669A-AD
Default
Min.
3
-
124
-
201
-
1
1
12,12
-
" "
-
04,04
-
"kg••"
-
SIWAREX WP321
Max.
-
-
-
65 635
-
-
-
-