Rs485 Protocol; Rs485 Baud Rate; Rs485 Character Parity; Rs485 Number Of Data Bits - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

Scale parameters and functions
8.13 DR 13 RS485 parameters
8.13.2

RS485 protocol

This parameter defines the protocol to be used for communication via the RS485 interface.
Function code
0 (default)
1
2
8.13.3

RS485 baud rate

This parameter defines the baud rate for the RS485 interface.
Function code
0
1
2
3 (default)
4
5
6
8.13.4

RS485 character parity

This parameter defines the character parity for the RS485 interface.
Value
0 (default)
1
8.13.5

RS485 number of data bits

This parameter defines the number of data bits for the RS485 interface.
Value
0
1 (de-
fault)
102
Baud rate
1 200 bps
2 400 bps
9 600 bps
19 200 bps
38 400 bps
57 600 bps
115 000 bps
Character parity
Even
Odd
Data bits
7
8
Protocol
No communication/protocol
Modbus RTU
SIEBERT display