Scale parameters and functions
8.3 DR 3 Calibration parameters
Parameter
SecureDisplay version
(Page 75)
Smallest zoom factor of
SecureDisplay (Page 75)
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Grid frequency (Page 75)
8.3.2
Scale name
You can select any name, but it may not exceed 12 characters. You can enter any
designation.
Note
The scale name cannot be changed after official verification.
8.3.3
Unit of weight
The following weight units are available for selection: milligram, gram, kilogram, metric ton,
ounce, pound, short ton, and long ton The weight unit selection has no effect on the internal
weight calculation. It involves only ASCII characters. Thus, all parameters with weight must
be specified with appropriate conversion when there is a change of weight unit.
8.3.4
Gross identifier
The gross identifier specifies the letter, B (for brutto) or G (for gross) to be used in the
display for a gross weight value.
66
Description
Format
SecureDisplay version UBYTE
Minimum zoom factor
USHORT
of SecureDisplay (%)
Reserve
FLOAT
Reserve
FLOAT
Reserve
FLOAT
Reserve
USHORT
Reserve
USHORT
Reserve
USHORT
Switchover of line
USHORT
frequency 50/60 Hz
0: 50 Hz
1: 60 Hz
Length
De-
Min
[bytes]
fault
12
"V3.0
-
0.10 "
2
0
-
4
0
-
4
0
-
4
0
-
2
0
-
2
0
-
2
0
0
2
0
0
Max
Write
Modbus
protec-
holding
tion
register
-
-
1069
-
-
1075
-
-
1076
-
-
1078
-
-
1080
-
-
1082
-
-
1083
1
-
1084
1
-
1085
SIWAREX WP251
Manual, 12/2015, A5E37203357A