Siemens SIWAREX WP251 Manual page 113

Electronic weighing system
Table of Contents

Advertisement

Variable
Behavior in
case of TH1
error
(Page 116)
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Note
Data type
0: Weighing cycle is
USHORT
not stopped and is
completed with
"Dosing completed"
1: Weighing cycle is
stopped. User can
use the "Continue"
command to check
the tolerance again
and the cycle is then
completed with
"Dosing completed"
in any case.
2: Weighing cycle is
stopped. User can
use the "Continue"
command to check
the tolerance again.
If there is still a tol-
erance error, the
scale goes to Stop
state again. This is
repeated until the
tolerance error is
eliminated (e.g. by
manually adding or
removing material).
Scale parameters and functions
8.21 DR 22 Tolerance parameters
Length
RW De-
Min
(bytes)
fault
2
rw
0
0
Max
Modbus
registers
0
1659