Siemens SIWAREX WP251 Manual page 153

Electronic weighing system
Table of Contents

Advertisement

Variable
Note
No. of weighings
Total number of all
weighings
No. of checked
Number of checked
weighings
weighings
No. of checks class
Number of checked
TH2 (absolute)
weighings above
TH2
No. of checks class
Number of checked
TH1 (absolute)
weighings above
TH1
No. of checks class
Number of weighings
"good" (absolute)
within tolerance band
1
No. of checks class
Number of checked
TL1 (absolute)
weighings below TL1
No. of checks class
Number of checked
TL2 (absolute)
weighings below TL2
No. of checks class
Number of checked
"bad" (absolute)
weighings outside
tolerance band 2
No. of checks class
Number of checked
TH2 (% of no. of
weighings above
weighings)
TH2 as a percentage
of the total number of
weighings
No. of checks class
Number of checked
TH1 (% of no. of
weighings above
weighings)
TH1 as a percentage
of the total number of
weighings
No. of checks class
Number of checked
"good" (% of no. of
weighings within
weighings)
tolerance band 1
as a percentage of
the total number of
weighings
No. of checks class
Number of checked
TL1 (% of no. of
weighings below TL1
weighings)
as a percentage of
the total number of
weighings
No. of checks class
Number of checked
TL2 (% of no. of
weighings below TL2
weighings)
as a percentage of
the total number of
weighings
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Type
Length
(bytes)
ULONG
4
ULONG
4
ULONG
4
ULONG
4
ULONG
4
ULONG
4
ULONG
4
ULONG
4
FLOAT
4
FLOAT
4
FLOAT
4
FLOAT
4
FLOAT
4
Scale parameters and functions
Rw
Default
Min.
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
r
0
0
8.33 DR 39 Statistics
Max.
Modbus
registers
-
4073
-
4075
-
4077
-
4079
-
4081
-
4083
-
4085
-
4087
100
4089
100
4091
100
4093
100
4095
100
4097
153