Dr 15 Preset Tare; Overview - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

Scale parameters and functions

8.15 DR 15 Preset tare

Table 8- 14
dw_ProcessValue1/2
Analog output digits
8.15
DR 15 Preset tare
8.15.1

Overview

This data record can be used for an external tare specification.
Procedure
● Enter the tare weight
● Transfer the data record to the scales
● Activate the preset tare weight with a command
Table 8- 15
Assignment of data record 15
Variable
Note
Data record
Contains no. of the data record
number
Length
Data record length information
Application
Information about which application the DR
belongs to
Version
Current data record version information
identifier
Preset tare
Tare preset 1
weight 1
(Page 105)
104
Structure of status of analog output, digital outputs, and digital inputs
Byte 0 of
Byte 1 of
dw_ProcessValue1/2
Analog output digits
HIGH
WORD
Byte 2 of
dw_ProcessValue1/2
Status of digital outputs
LOW
Bit 0 = status DQ 0
Bit 1 = status DQ 1
Bit 2 = status DQ 2
Bit 3 = status DQ 3
Type
Length
(bytes)
USHORT
2
USHORT
2
USHORT
2
USHORT
2
FLOAT
4
Byte 3 of
dw_ProcessValue1/2
Status of digital inputs
Bit 0 = status DI 0
Bit 1 = status DI 1
Bit 2 = status DI 2
Bit 3 = status DI 3
Rw
De-
Min
Max.
fault
.
r
15
-
-
r
28
-
-
r
105
-
-
r
1
1
65635
rw
0
0
Depends
on
specifi-
cation in
DR 3
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Modbus
registers
1578
1579
1580
1581
1582

Advertisement