Variable
Capture of
weighings into
statistics
(Page 117)
Reserve
Reserve
Reserve
Reserve
8.21.2

Parameter relation

The parameters are used to define how the specified tolerance limits TH2, TH1, TL1 and
TL2 are to be interpreted. The following options are available:
Function code
0 (default)
1
2
3
In general, the currently valid tolerance limits in data record 31 are output in the weight unit.
When function codes 2 and 3 are selected, the entered tolerance limits TH2, TH1, TL1 and
TL2 are ignored because the limits are calculated automatically based on the OIML
Recommendation.
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Note
Data type
0: All dosings (with
USHORT
tolerance check) are
included following
"Dosing completed"
in the calculated
statistics
1: Only dosings
(with tolerance
check) of "GOOD"
class are included
following "Dosing
completed" in the
calculated statistics
2: Only dosings
(with tolerance
check) of "BAD"
class are not includ-
ed following "Dosing
completed" in the
calculated statistics
Reserve
FLOAT
Reserve
FLOAT
Reserve
SHORT
Reserve
SHORT
Meaning
The tolerance limits are interpreted as percentages of the set point in DS 20
The tolerance limits are interpreted as absolute weight values
The tolerance limits are calculated based on OIML R61 "Limits of error on verifica-
tion Class X1".
The tolerance limits are calculated based on OIML R61 "Maximum permissible
errors in service Class X1".
Scale parameters and functions
8.21 DR 22 Tolerance parameters
Length
RW De-
Min
(bytes)
fault
2
rw
0
0
4
rw
0
0
4
rw
0
0
2
rw
0
0
2
rw
0
0
Max
Modbus
registers
0
1665
0
1666
0
1668
0
1670
-
1671
115