Calibration; Sending/Receiving A Data Record / In Siwatool V7 - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

different offline parameters will be sent to the scale and overwrite previously active and
intentionally defined parameters.
You must subsequently enter the required parameters in data record DR 10 and send these
to the module.
Image 7-4
● No. of mechanical support points
platform is mounted on four load cells, the number of mechanical support points if 4.
mountings, there are 3 mechanical support points.
● Characteristic value of a load cell in mV/V, or the mean value of the characteristic values
if there is more than one load cell
● Rated load of a load cell
● Load cell manufacturer
service case.
● Load cell order number
service case.
7.4.5

Calibration

● Provided that the calibration weight 0 was specified with 0 (typical case), the scale must
now be empty (only mechanical dead load).
● Activate the "Set Calibration Point 0" (60) command.
● Place the previously defined "Calibration weight 1" on the scale
● Activate the "Set Calibration Point 1" (61) command.
● Optional: Place the previously defined "Calibration weight 2" on the scale
● Activate the "Set Calibration Point 2" (62) command.
SIWAREX WP251
Manual, 12/2015, A5E37203357A

Sending/receiving a data record / in SIWATOOL V7

If WP251 is connected, for example, to a platform weighing machine in which the
If it is connected to a tank that is mounted on one load cell and two fixed point
The manufacturer of the installed load cells can be quickly and easily identified in a
The order number of the installed load cells can be quickly and easily identified in a
→The weight display should now indicate 0.
→ The calibration weight 1 should be displayed in the weight display.
→ The calibration weight 2 should be displayed in the weight display.
7.4 Quick calibration with calibration weights and SIWATOOL
Commissioning
47

Advertisement

Table of Contents
loading