Dr 20 Single Set Point; Overview; Single Set Point - Siemens SIWAREX WP251 Manual

Electronic weighing system
Table of Contents

Advertisement

8.19

DR 20 Single set point

8.19.1

Overview

The set point amount to be dosed is specified in the data record.
Procedure
● Specify the desired set point
● Transfer DR 20 to SIWAREX WP251
Table 8- 19
Variable
Data record
number
Length
Application
Version identifi-
er

Single set point

(Page 109)
Reserve
Reserve
Reserve
8.19.2
Single set point
The set point defines the weight to be dosed for a single dosing. It is specified based on the
weight unit set in DR 3 and must not exceed the maximum permissible set point from DR 25.
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Assignment of data record 20
Note
Contains no. of the
data record
Data record length
information
Information about
which application
the data record
belongs to
Current data record
version information
Set point for a single
dosing
Reserve
Reserve
Reserve
Type
Length
Rw
(bytes)
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
FLOAT
4
rw
FLOAT
4
rw
USHORT
2
rw
USHORT
2
rw
Scale parameters and functions
8.19 DR 20 Single set point
De-
Min
Max.
Modbus
fault
.
registers
20
-
-
1624
20
-
-
1625
105
-
-
1626
1
1
6563
1627
5
50.0
0
Lim-
1628
ited
in DR
25
-
-
-
1630
-
-
-
1632
-
-
-
1633
109

Advertisement

Table of Contents
loading