Variable
Note
"Fine" set value for
% value referenced to 0/4-20
analogue output
mA
(Page 129)
Minimum automatic
Taring occurs at dosing start
tare weight
only if gross>minimum tare
(Page 129)
weight
0: No monitoring
(specification in % referenced
to "Max. weight DS 3")
Maximum automatic
Taring occurs at dosing start
tare weight
only if gross<maximum tare
(Page 129)
weight
0: No monitoring
(specification in % referenced
to "Max. weight DS 3")
Maximum weighing
Monitoring of the dosing time.
time (Page 129)
Once this time has elapsed, a
technology message is output
(0: no message)
Reserve
Reserve
Weighing start
0: No zero setting/taring
options (Page 130)
1: With zero setting
2: With taring
3: With preset tare weight from
DR 15
4: With preset tare weight from
SIMATIC I/O
Cycle time for au-
Time after which the next dos-
tomatic zero setting
ing must be set to zero.
(Page 130)
(only relevant for
AWI)
Number of weigh-
Number of dosing cycles that
ings without auto-
are not tared/zeroed
matic taring/zero
setting (Page 130)
Check stop
Bit 0: -
(Page 130) points
Bit 1: Dosing goes to check
stop after step 1, if test stop
command was received
Bit 2: Dosing goes to check
stop after step 2, ...
Bit n: Dosing goes to check
stop after step n, ...
Reserve
Reserve
Reserve
Reserve
SIWAREX WP251
Manual, 12/2015, A5E37203357A
Type
Length
RW
(bytes)
FLOAT
4
rw
FLOAT
4
rw
FLOAT
4
rw
TIME
4
rw
USHORT
2
rw
USHORT
2
rw
TIME
4
rw
USHORT
2
rw
USHORT
2
rw
ULONG
4
rw
USHORT
2
rw
Scale parameters and functions
8.24 DR 25 Dosing device parameters
De-
Min.
Max.
fault
20
0
< Coarse
signal
value
0
0
< Maxi-
mum tare
weight DR
3
0
0
≤ Maxi-
mum tare
weight DR
3
0
0
0
0
0
0
2
0
0
0
0
0
0
0
65,535
0
0
0
0
0
0
0
0
0
Modbus
registers
1730
1732
1734
1736
1738
1739
1740
1742
1743
1744
1746