11.21 DR 20 Message configuration

11.21
DR 20 Message configuration
You can suppress technological messages in data record DR 20. If you set the value for an
individual message to "0", this message is no longer generated as if it did not exist. We
recommend that you do not suppress messages.
NOTICE
Suppressing a message
Suppressing messages could mean that a fault in the belt scale is not recognized.
Procedure
● Define the value for a message to be suppressed to 0
● Transfer the data record to the scale
Table 11- 21 Assignment of data record 20
Variable
Data record number
Length
Application
Version identifier
2000 Technology error
Reserve
2002 Trace error
2003 Zeroing aborted
3001 Totalizer error
2004 Trace memory full
3002 Calibration procedure
interrupted
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
150
Note
Contains no. of data rec-
ord
Data record length infor-
mation
Information about which
application the data rec-
ord belongs to
Information about current
data record version
Type
L
Rw
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
BIT
2
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
0
rw
BIT
rw
BIT
rw
BIT
rw
BIT
rw
USHORT
rw
Default
Min.
Max.
20
-
-
12
-
-
104
-
-
1
1
255
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
1
-
-
-
-
SIWAREX WT241
Manual, 05/2015, A5E36046748A
Register
3000
3001
3002
3003
3004.16
3004.15
3004.14
3004.13
3004.12
3004.11
3004.10
3004.9
3004.8
3004.7
3004.6
3004.5
3004.4
3004.3
3004.2
3004.1
3005.16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents