APPENDIX
App. 7 Using the neutral point of a 3-phase 400 V AC class power supply for inputting a 1-
phase 200 V AC class power supply
CAUTION
You can use the neutral point of a 3-phase 400 V AC class power supply to input a 1-phase 200 V AC class
power supply to the servo amplifier.
If necessary, use a step-down transformer to decrease the power supply voltage to 200 V AC to 240 V AC.
(1) For MR-JE-10A to MR-JE-100A
Note 1. If necessary, use a step-down transformer to decrease the power supply voltage to 200 V AC to
Do not input a 3-phase 400 V AC class power supply directly to the 200 V class
servo amplifier. Otherwise, it may cause a malfunction.
3-phase
400 V AC class
Do not connect anything.
3-phase
400 V AC class
Neutral
200 V AC to 240 V AC (Note 1)
point
Do not connect anything.
240 V AC.
2. Connect the 1-phase 200 V AC to 240 V AC power supply to L1 and L3. One of the connecting
destinations is different from MR-JE-200A servo amplifier's.
Emergency
stop switch
MCCB
MC
Emergency
stop switch
MCCB
App. - 19
OFF
ON
Mal-
function
MC
RA1
Servo amplifier
CNP1
OFF
ON
Mal-
function
MC
RA1
Servo amplifier
CNP1 (Note 2)
MC
L1
L2
L3
MC
SK
MC
SK