1. FUNCTIONS AND CONFIGURATION
Model: MR-JE-
Ambient
temperature
Ambient
humidity
Environment
Ambience
Altitude
Vibration resistance
Mass
Note 1. 0.3 A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. When closely mounting the servo amplifier of 3.5 kW or less, operate them at the ambient temperatures of 0 °C to 45 °C or at
75% or smaller effective load ratio.
3. 1 Mpulse/s or lower commands are supported in the initial setting. When inputting commands over 1 Mpulse/s and 4 Mpulses/s
or lower, change the setting in [Pr. PA13].
4. The RS-422 communication function is supported by servo amplifier manufactured in December 2013 or later. Refer to section
1.6 (1) for the year and month of manufacture.
5. These are current values for 3-phase power supply.
6. When using 1-phase 200 V AC to 240 V AC power supply, operate the servo amplifier at 75% or smaller effective load ratio.
7. The RS-485 communication function is available with servo amplifiers manufactured in May 2015 or later. Refer to section 1.6
(1) for the year and month of manufacture.
8. Follow the restrictions in section 2.6 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level.
10A
20A
Operation
Storage
Operation
Storage
free from corrosive gas, flammable gas, oil mist, dust, and dirt
[kg]
40A
70A
0 °C to 55 °C (non-freezing)
-20 °C to 65 °C (non-freezing)
5 %RH to 90 %RH (non-condensing)
Indoors (no direct sunlight),
2000 m or less above sea level (Note 8)
5.9 m/s
, at 10 Hz to 55 Hz (directions of X, Y and Z axes)
2
0.8
1 - 5
100A
200A
1.5
2.1
300A