3. SIGNALS AND WIRING
Normally, connect as follows.
(b) Speed limit value selection
To select VLA (Analog speed limit) and a speed limit value of internal speed limit 1 to 7, enable SP1
(Speed selection 1), SP2 (Speed selection 2), and SP3 (Speed selection 3) with [Pr. PD03] to [Pr.
PD20].
When the internal speed limits 1 to 7 are used to limit a speed, the speed does not vary with the
ambient temperature.
(c) VLC (Limiting speed)
VLC turns on when the servo motor speed reaches a speed limited with internal speed limits 1 to 7
or analog speed limit.
Servo amplifier
-10 V to +10 V
VLA
LG
SD
(Note) Input device
SP3
SP2
SP1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
Note. 0: Off
1: On
3 - 41
Speed limit
0
VLA (Analog speed limit)
1
Pr. PC05 Internal speed limit 1
0
Pr. PC06 Internal speed limit 2
1
Pr. PC07 Internal speed limit 3
0
Pr. PC08 Internal speed limit 4
1
Pr. PC09 Internal speed limit 5
0
Pr. PC10 Internal speed limit 6
1
Pr. PC11 Internal speed limit 7

Hide quick links: