Mitsubishi Electric MR-JE-_A Instruction Manual page 166

General-purpose ac servo amplifier
Hide thumbs Also See for MR-JE-_A:
Table of Contents

Advertisement

5. PARAMETERS
No./symbol/
Setting
name
digit
PB51
Set the shape of the machine resonance suppression filter 5.
NHQ5
When you select "Enabled (_ _ _ 1)" of "Robust filter selection" in [Pr. PE41], the machine resonance suppression
filter 5 is not available.
Notch shape
selection 5
_ _ _ x Machine resonance suppression filter 5 selection
0: Disabled
1: Enabled
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
_ x _ _ Notch width selection
0: α = 2
1: α = 3
2: α = 4
3: α = 5
x _ _ _ For manufacturer setting
PB52
Set the vibration frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
VRF21
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
Vibration
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
suppression
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
control 2 -
Vibration
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If a
frequency
value out of the range is set, the vibration suppression control will be disabled. Refer
to section 7.1.5 for details.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.1 to 300.0
PB53
Set the resonance frequency for vibration suppression control 2 to suppress low-
frequency machine vibration.
VRF22
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
Vibration
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
suppression
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
control 2 -
Resonance
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If a
frequency
value out of the range is set, the vibration suppression control will be disabled. Refer
to section 7.1.5 for details.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.1 to 300.0
PB54
Set a damping of the vibration frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
VRF23
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
Vibration
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
suppression
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
control 2 -
Vibration
Refer to section 7.1.5 for details.
frequency
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
damping
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.00 to 0.30
PB55
Set a damping of the resonance frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
VRF24
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
Vibration
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When
suppression
"Manual setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
control 2 -
Resonance
Refer to section 7.1.5 for details.
frequency
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
damping
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.00 to 0.30
Function
5 - 27
Initial
Control mode
value
P
S
T
[unit]
0h
0h
0h
0h
100.0
[Hz]
100.0
[Hz]
0.00
0.00

Hide quick links: