5. PARAMETERS
No./symbol/
Setting
name
digit
PF24
_ _ _ x
Oscillation detection alarm selection
*OSCL2
Select alarm or warning when an oscillation continues at a filter readjustment
sensitivity level of [Pr. PF23].
Vibration
tough drive
The digit is continuously enabled regardless of the vibration tough drive in [Pr.
function
PA20].
selection
0: [AL. 54 Oscillation detection] will occur at oscillation detection.
1: [AL. F3.1 Oscillation detection warning] will occur at oscillation detection.
2: Oscillation detection function disabled
_ _ x _
For manufacturer setting
_ x _ _
x _ _ _
PF25
Set the time of the [AL. 10.1 Voltage drop in the power] occurrence.
CVAT
To disable the parameter, select "Disabled (_ 0 _ _)" of "Instantaneous power failure
tough drive selection" in [Pr. PA20].
instantaneous
power failure
When "Enabled (_ 1 _ _)" is selected of "Instantaneous power failure tough drive
tough drive -
selection" in [Pr. PA20], the power should be off for the setting value of this
detection time
parameter + 1.5 s or more before cycling the power to enable a parameter whose
symbol is preceded by "*".
Setting range: 30 to 2000
PF31
Set a servo motor speed to divide a friction estimation area into high and low for the
friction estimation process of the machine diagnosis.
FRIC
However, setting "0" will be the value half of the rated speed.
Machine
diagnosis
When your operation pattern is under rated speed, we recommend that you set half
function -
value to the maximum speed with this.
Friction
judgment
speed
Forward rotation
direction
Servo motor
speed
Reverse rotation
direction
Setting range: 0 to permissible speed
Function
Maximum speed in operation
0 r/min
Operation pattern
5 - 47
[Pr. PF31] setting
Initial
Control mode
value
P
S
T
[unit]
0h
0h
0h
0h
200
[ms]
0
[r/min]