3. SIGNALS AND WIRING
(2) Cable connection procedure
(a) Fabrication on cable insulator
Refer to table 3.1 and 3.2 for stripped length of cable insulator. The appropriate stripped length of
cables depends on their type, etc. Set the length considering their status.
Twist strands lightly and straighten them as follows.
You can also use a ferrule to connect with the connectors. When you use a ferrule, use the following
ferrules and crimp terminal.
Servo amplifier
MR-JE-10A to
MR-JE-100A
MR-JE-200A to
MR-JE-300A
(b) Inserting wire
Insert only one wire or ferrule to each wire insertion hole.
Insert the open tool as follows and push down it to open the spring. While the open tool is pushed
down, insert the stripped wire into the wire insertion hole. Check the wire insertion depth, and make
sure that the cable insulator will not be caught by the spring and that the conductive part of the
stripped wire will not be exposed.
Release the open tool to fix the wire. Pull the wire lightly to confirm that the wire is surely connected.
In addition, make sure that no conductor wire sticks out of the connector.
The following shows a connection example of the CNP2 connector for 2 kW and 3 kW.
Insulator
Stripped length
Loose and bent strands
Ferrule model (Phoenix Contact)
Wire size
For one
AWG 16
AI1.5-10BK
AWG 14
AI2.5-10BU
AWG 16
AI1.5-10BK
AWG 14
AI2.5-10BU
AWG 12
AI4-10GY
3 - 19
Core
Twist and straighten
the strands.
For two
AI-TWIN2×1.5-10BK
AI-TWIN2×1.5-10BK
AI-TWIN2×2.5-10BU
1) Push down the open tool.
3) Release the open tool to fix the wire.
2) Insert the wire.
Crimp terminal
(Phoenix Contact)
CRIMPFOX-ZA3