Emergency power-off event

|
|
|
|
|
|
|

Checking the safety labels on the SAN Volume Controller

Using the following inspection checklist as a guide, inspect the UPS for unsafe
conditions. If necessary, see any suitable safety publications.
1. If any equipment has been damaged during the shipment, keep the shipping
cartons and packing materials.
2. File a claim for shipping damage within fifteen days of receipt of the equipment.
The SAN Volume Controller and uninterruptible power supplies (UPSs) will
occasionally undergo an emergency power-off (EPO) shutdown.
In the event of a room EPO shutdown, the UPS 5115 will automatically shut down
within 5 minutes of the input power being removed. When the UPS 5125 detects a
loss of input power, this is reported to the SAN Volume Controller which completes
the process of shutting down the output from the UPS 5125 within 5 minutes.
Attention:
If an EPO event occurs and the UPS 5125 is not connected to at least
one operational SAN Volume Controller, you must unplug the output cables of the
UPS 5125 to remove output power from the UPS.
Ensure that you check and understand the safety labels on the SAN Volume
Controller.
The following steps describe how to check the labels on the SAN Volume
Controller.
Perform the following label checks:
1. Agency/ratings label. See Figure 1.
MACHINE TYPE 2145
MODEL:
SAN JOSE
CA, USA
4F2
Marca Registrada
RATING:
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions: (1) this device may not
100-240V ,
50/60Hz
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
3.5- 1.75A
undesired operation.
E-D019-00-3904(A)
P/N 64P7837
XX
Figure 1. Agency/ratings label for the SAN Volume Controller
2. No user access label. See Figure 2.
Figure 2. No user access label for the SAN Volume Controller
3. Class 1 laser label. See Figure 3 on page xxii.
Registered Trademark
This machine is manufactured
of International Business
from new parts or new and
Machines Corporation
used parts.
IBM Canada Ltd.
Registered User
CANADA ICES/NMB-003 Class/Classe (A)
LR34074C
Æ
IEC 60950
C
US
ME01
R33026
A
VCCI-A
xxi
About this guide

Advertisement

Table of Contents
loading