caution, attention notices, and the translation of the safety labels, see the IBM
TotalStorage SAN Volume Controller: Translated Safety Notices.
CAUTION:
The UPS contains its own energy source (batteries). The output receptacles
might carry live voltage even when the UPS is not connected to an AC supply.
(11)
CAUTION:
Do not remove or unplug the input cord when the UPS is turned on. This
removes the safety ground from the UPS and the equipment connected to the
UPS. (12)
CAUTION:
To reduce the risk of fire or electric shock, install the UPS in a temperature
and humidity controlled, indoor environment, free of conductive
contaminants. Ambient temperature must not exceed 40°C (104°F). Do not
operate near water or excessive humidity (95% maximum). (13)
CAUTION:
To comply with international standards and wiring regulations, the total
equipment connected to the output of the UPS 5125 must not have an earth
leakage current greater than 2.5 milliamperes and for the UPS 5115 it must
not be greater than 3.5 milliamperes. (14)
CAUTION:
To avoid any hazard from the rack tipping forward when boxes are installed,
observe all safety precautions for the rack into which you are installing the
device.
The UPS 5125 weighs 39 kg (86 lb) with the electronics assembly and the
battery assembly installed:
v Do not attempt to lift the UPS 5125 by yourself. Ask another service
v Remove the battery assembly from the UPS 5125 before removing the UPS
v Do not attempt to install the UPS 5125 into the rack unless the electronics
CAUTION:
The electronics assembly for the UPS 5125 weighs 6.4 kg (14 lb). Take care
when you remove it from the UPS 5125. (16)
CAUTION:
The UPS 5125 battery unit weighs 21 kg (45 lb). Do not attempt to lift the UPS
5125 battery unit by yourself. Ask another service representative for aid. (18)
CAUTION:
Do not dispose of the battery in a fire. The battery might explode. Correct
disposal of the battery is required. Refer to your local regulations for disposal
requirements. (20)

Caution notices for the SAN Volume Controller

Ensure that you understand the caution notices for the SAN Volume Controller.
xviii
IBM TotalStorage SAN Volume Controller: Installation Guide
representative for assistance.
from the shipping carton.
assembly and the battery assembly have been removed.