Transferring The Setting From The Memory Card - Siemens sinamics G120 Operating Instructions Manual

Low voltage inverters chassis devices with cu250s-2 control units and encoder evaluation
Hide thumbs Also See for sinamics G120:
Table of Contents

Advertisement

7.1.2

Transferring the setting from the memory card

Automatically transferring
Precondition
The inverter power supply has been switched off.
Procedure
Proceed as follows to automatically transfer your settings:
1. Insert the memory card into
the inverter.
2. Then switch on the inverter
power supply.
If there is valid parameter data on the memory card, then the inverter accepts the data from
the memory card.
Manually transferring
Preconditions
• The inverter power supply has been switched on.
• No memory card is inserted in the inverter.
Converter with CU250S-2 Control Unit
Operating Instructions, 01/2016, FW V4.7 SP6, A5E31759476B AE
Backing up data and series commissioning
7.1 Saving settings on a memory card
355