Buell S1 Lightning Workshop Manual page 281

1997 year
Table of Contents

Advertisement

Continuous or No Spark at Plug
STEP 1
1.
Ignition switch on.
2.
Multimeter red wire to white wire terminal,
black wire to ground.
Meter should register 12 VDC ± 1.0 volt. If
3.
meter is correct, proceed to
STEP 2
1.
Remove pink (module) wire from coil
terminal.
2.
Ignition switch on.
3.
Multimeter red wire alternately to white
wire terminal and to pink wire terminal.
4.
Meter should register 12 VDC at both
terminals. If meter is correct, proceed
to
STEP
3.
STEP 3
1.
Pink (module) wire disconnected.
2.
Ignition switch on.
3.
Jumper wire – connect capacitor wire to
pink wire terminal.
4.
Connect both wires to common ground.
5.
Momentarily touch ground wire to pink wire
terminal. When you remove the wire, there
should be a spark at plug. If spark occurs,
proceed to
STEP
4.
STEP 4
1.
Reconnect pink wire to coil.
2.
Ignition switch on.
3.
Disconnect sensor.
4.
Connector from module–multimeter red
wire to red wire socket and multimeter
black wire to black/white pin. Should regis-
ter 12 VDC ± 0.5 volts. If meter is correct,
proceed to
STEP
5.
7-6
b0077x7x
STEP
2.
b0078x7x
b0079x7x
x0043ax7x
A. Green
B. Black/white pin
C. Red from module
IF NO POWER
Check circuit breaker, ignition relay,
loose wires, switches.
To tach
IF NO POWER
Check coil resistance. See COIL
later in this section.
If resistance is OK check spark.
See
STEP
IF NO SPARK
Replace coil.
Jumper
B
A
IF NO POWER
Check module ground and power
C
wire to module for loose connec-
tions. See Resistance Test which
follows. Check spark,
3.
STEP
5.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents