7210 SAS M, T, X, R6, Mxp Interface Configuration Guide
The software monitors the PoE port and detect faults and events and raises traps, along
with displaying the same in the status of the port.
Events and faults detected and notified to the user are:
→ Supplying power event – This event is generated when power is supplied to a
connected PoE device after successful detection and classification.
→ Denied power event – This event is generated when power is denied to a connected
PoE device after successful detection and classification.
→ Disconnect event – This event is generated when a connected PoE device is
disconnected from the port and, stops drawing power from the node.
→ Fault events are generated for events such as overload, short-circuit, and other events.
Software clears the fault when the fault no longer exists.
If a port is enabled for PoE is shutdown, then the power supplied to the port is disabled. It
restores when the no shutdown command is executed, if the request does not exceed the
power budget.
Interface Configuration